Home

Class Schedule

µÚ·Î ¸ñÂ÷·Î
2 Æí          ¿ë         Á¢

     ¾Ð·ÂÁ¶Á¤±âÀÇ ÀÛµ¿¿ø¸®

(a) ¾Ð·Â Á¶Á¤ valve°¡ °í¾Ð½Ç°ú Àú¾Æ½ÇÀÇ Åë·Î¸¦ ¸·°í ÀÖ´Ù.



(b) Á¶Á¤ handleÀ» µ¹·Á diapharagm(°Ý¸·)¹Ð¾î ¾Ð·ÂÁ¶Á¤ valve¸¦ ¿­¸é °í¾Ð½ÇÀÇ gas°¡ Àú¾Ð½Ç·Î À¯ÀԵȴÙ.



(c) Àú¾Ð½ÇÀÇ ¾Ð·ÂÀÌ ³ô¾ÆÁö¸é diapharagm(°Ý¸·)ÀÌ ¿À¸¥ÂÊÀ¸·Î º¯ÇüÇÏ¿© Á¶Á¤ valve°¡ ºÎºÐÀûÀ¸·Î ¶Ç´Â ¿ÏÀüÈ÷ ´ÝÇô ¼³Á¤µÈ ¾çÃøÀÇ spring·Â¿¡ ÀÇÇÏ¿© Àú¾Ð½Ç·ÎÀÇ À¯ÀÔÀÌ ÀÚµ¿ Á¶Àý µÈ´Ù.


À§ÀÇ (c)¸¦ ¼³¸íÇÏ´Â animation


# Bourdon°ü ¾Ð·Â°è(Bourdon tube pressure gage)

                     
ÇÑÂÊ ³¡ÀÌ ¸·Èù CÀÚÇüÀ¸·Î ±ÁÈù Ÿ¿øÇü ´Ü¸éÀ» °®´Â Bourdon tube ³»¿¡ ¾Ð·ÂÀ¯Ã¼°¡ À¯ÀÔµÇ¸é ¾Ð·Â¿¡ ºñ·ÊÇÏ¿© Bourdon tube°¡ ÆìÁö°ÔµÇ°í, Bourdon tubeÀÇ º¯ÇüÀº sector gear¸¦ °ÅÃÄ ÁöħÀ» ȸÀü½ÃÄÑ ÀÛ¿ë¾Ð·ÂÀ» Áö½ÃÇÑ´Ù.



Pressure regulator:

The pressure regulators enable the user to reduce the high pressure contained in the cylinder to a usable working pressure. There are several handling and set up procedures that are important to the overall operation of the pressure regulator. The pressure regulator on each tank shows two things:

  1. Cylinder pressure (How much gas is in the cylinder)
  2. Working or line pressure
Installing the regulators
  1. Before installing the regulator crack the cylinder valve to clean out any dirt or dust.
  2. Mount the regulator onto the cylinder.
    • Ensure that the oxygen pressure regulator is on the oxygen tank.
  3. Do Not over tighten regulator nut.
  4. Before opening the cylinder valve ensure that the pressure regulator screws are released (turned out).
  5. Never use oil or grease on the regulators.
    • Frictional heat as a result of high pressures can cause oil to ignite and possibly cause an explosion.
µÚ·Î ¸ñÂ÷·Î À§·Î